Like the CESM1.1 series, the CESM1.2 series also has the new capability to run multiple component instances under one model executable. The only caveat to this usage is that if N multiple instances of any one active component is used, then N multiple instances of ALL active components are required. More details are discussed below. The primary motivation for this development was to be able to run an ensemble Kalman-Filter for data assimilation and parameter estimation (e.g. UQ). However, it also provides you with the ability to run a set of experiments within a single CESM executable where each instance can have a different namelist, and have all the output go to one directory.

In the following an F compset will be used as an illustration. Utilizing the multiple instance code involves the following steps:

  1. create the case

    > create_newcase -case Fmulti -compset F  -res ne30_g16 -mach hopper
    > cd Fmulti
  2. Lets assume the following out of the box pe-layout for hopper:

    <entry id="NTASKS_ATM"   value="128"  />
    <entry id="NTHRDS_ATM"   value="1"  />
    <entry id="ROOTPE_ATM"   value="0"  />
    <entry id="NINST_ATM"   value="1"  />
    <entry id="NINST_ATM_LAYOUT"   value="concurrent"  />
    
    <entry id="NTASKS_LND"   value="128"  />
    <entry id="NTHRDS_LND"   value="1"  />
    <entry id="ROOTPE_LND"   value="0"  />
    <entry id="NINST_LND"   value="1"  />
    <entry id="NINST_LND_LAYOUT"   value="concurrent"  />
    
    <entry id="NTASKS_ICE"   value="128"  />
    <entry id="NTHRDS_ICE"   value="1"  />
    <entry id="ROOTPE_ICE"   value="0"  />
    <entry id="NINST_ICE"   value="1"  />
    <entry id="NINST_ICE_LAYOUT"   value="concurrent"  />
    
    <entry id="NTASKS_OCN"   value="128"  />
    <entry id="NTHRDS_OCN"   value="1"  />
    <entry id="ROOTPE_OCN"   value="0"  />
    <entry id="NINST_OCN"   value="1"  />
    <entry id="NINST_OCN_LAYOUT"   value="concurrent"  />
    
    <entry id="NTASKS_GLC"   value="128"  />
    <entry id="NTHRDS_GLC"   value="1"  />
    <entry id="ROOTPE_GLC"   value="0"  />
    <entry id="NINST_GLC"   value="1"  />
    <entry id="NINST_GLC_LAYOUT"   value="concurrent"  />
    
    <entry id="NTASKS_WAV"   value="128"  />
    <entry id="NTHRDS_WAV"   value="1"  />
    <entry id="ROOTPE_WAV"   value="0"  />
    <entry id="NINST_WAV"   value="1"  />
    <entry id="NINST_WAV_LAYOUT"   value="concurrent"  />
    
    <entry id="NTASKS_CPL"   value="128"  />
    <entry id="NTHRDS_CPL"   value="1"  />
    <entry id="ROOTPE_CPL"   value="0"  />

    For an F compset, only atm, lnd, rof are full prognostic components. The ocn is a prescribed data component, cice is a mixed prescribed/prognostic component (ice-coverage is prescribed) and glc and wav are stub components. Lets say we want to run 2 instances of CAM in this experiment. The current implementation of multi-instances will also require you to run 2 instances of CLM, CICE and RTM. However, you have the flexibility to run either 1 or 2 instances of DOCN (we can ignore glc and wav since they do not do anything in this compset). To run 2 instances of CAM, CLM, CICE, RTM and DOCN, all you need to do is to change NINST_ATM, NINST_LND, NINST_ICE, NINST_ROF and NINST_DOCN above from 1 to 2. This will result in the following env_mach_pes.xml file:

    <entry id="NTASKS_ATM"   value="128"  />
    <entry id="NTHRDS_ATM"   value="1"  />
    <entry id="ROOTPE_ATM"   value="0"  />
    <entry id="NINST_ATM"   value="2"  />
    <entry id="NINST_ATM_LAYOUT"   value="concurrent"  />
    
    <entry id="NTASKS_LND"   value="128"  />
    <entry id="NTHRDS_LND"   value="1"  />
    <entry id="ROOTPE_LND"   value="0"  />
    <entry id="NINST_LND"   value="2"  />
    <entry id="NINST_LND_LAYOUT"   value="concurrent"  />
    
    <entry id="NTASKS_ICE"   value="128"  />
    <entry id="NTHRDS_ICE"   value="1"  />
    <entry id="ROOTPE_ICE"   value="0"  />
    <entry id="NINST_ICE"   value="2"  />
    <entry id="NINST_ICE_LAYOUT"   value="concurrent"  />
    
    <entry id="NTASKS_ROF"   value="128"  />
    <entry id="NTHRDS_ROF"   value="1"  />
    <entry id="ROOTPE_ROF"   value="0"  />
    <entry id="NINST_ROF"   value="2"  />
    <entry id="NINST_ROF_LAYOUT"   value="concurrent"  />
    
    <entry id="NTASKS_OCN"   value="128"  />
    <entry id="NTHRDS_OCN"   value="1"  />
    <entry id="ROOTPE_OCN"   value="0"  />
    <entry id="NINST_OCN"   value="2"  />
    <entry id="NINST_OCN_LAYOUT"   value="concurrent"  />
    
    <entry id="NTASKS_GLC"   value="128"  />
    <entry id="NTHRDS_GLC"   value="1"  />
    <entry id="ROOTPE_GLC"   value="0"  />
    <entry id="NINST_GLC"   value="1"  />
    <entry id="NINST_GLC_LAYOUT"   value="concurrent"  />
    
    <entry id="NTASKS_CPL"   value="128"  />
    <entry id="NTHRDS_CPL"   value="1"  />
    <entry id="ROOTPE_CPL"   value="0"  />

    As a result of this, you will have 2 instances of CAM, CLM and CICE (prescribed) and RTM, each running concurrently on 64 MPI tasks - and only 1 instance of DOCN.

  3. A separate user_nl_xxx_NNNN file (where NNNN is the number of the component instances) will be generated when cesm_setup is called. In particular, calling cesm_setup with the above env_mach_pes.xml file will result in the following user_nl_* files in $CASEROOT

    user_nl_cam_0001
    user_nl_cam_0002
    user_nl_cice_0001
    user_nl_cice_0002
    user_nl_clm_0001
    user_nl_clm_0002
    user_nl_cpl
    user_nl_docn_0001
    user_nl_docn_0002
    user_nl_rtm_0001
    user_nl_rtm_0002

    and the following *_in_* files and *txt* files in $CASEROOT/CaseDocs:

    atm_in_0001
    atm_in_0002
    docn.streams.txt.prescribed_0001
    docn.streams.txt.prescribed_0002
    docn_in_0001
    docn_in_0002
    docn_ocn_in_0001
    docn_ocn_in_0002
    drv_flds_in
    drv_in
    ice_in_0001
    ice_in_0002
    lnd_in_0001
    lnd_in_0002
    rof_in_0001
    rof_in_0002

    The namelist for each component instance can be modified by changing the corresponding user_nl_xxx_NNNN file for that component instance. Modifying the user_nl_cam_0002 will result in the namelist changes you put in to be active ONLY for instance 2 of CAM. To change the DOCN stream txt file instance 0002, you should place a copy of docn.streams.txt.prescribed_0002 in $CASEROOT with the name user_docn.streams.txt.prescribed_0002 and modify it accordlingly.

It is also important to stress the following points:

  1. Different component instances can ONLY differ by differences in namelist settings - they are ALL using the same model executable.

  2. Only 1 coupler component is supported in the CESM1.2 series multiple instance implementation.

  3. user_nl_* files once they are created by cesm_setup ARE NOT removed by calling cesm_setup -clean. The same is true for Macros files.

  4. In general, you should run multiple instances concurrently (the default setting in env_mach_pes.xml). The serial setting is only for EXPERT USERS in upcoming development code implementations.